ESX6146 / ESL6146
EMX5141 /
EM7761 / EM12181
EH3030
ELX6146
TDR6146/7761/3030
LD6146 / AL5141
MF6146
ARS3624
Specification


Realizes highly automated TDR measurement of high speed PCB's.


Controlled Impedance & Low Resistance Measurements for the high end user of TDR and Resistance measurements.
The TDR3030 incorporates a High Accuracy mechanical stage capable of testing pad size to 0.0012" (30µm). With high-speed packaging right around the corner, the TDR3030 is ready for High Accuracy/Resolution type measurements.

Measurement item: Controlled Impedance, Low Resistance
Testable Terminals: C4 Bump, Pin for PGA, Pad for BGA
Interfaces for : Tektronix and Agilent/HP meters
Repeatability: ±0.0001"(±3µm)

Basic Principle of
TDR Measurement
By utilizing Coaxial Probe, high frequency signal that is generated by TDR Generator is loaded on a pattern of PCB. The reflection wave against the signal is measured by the Sampler, and thus the Impedance mismatch is calculated.
Ionizer The Ionizer attached to the arm introduces an air purge prior to the test and neutralizes the static charge of the PCB.
Otherwise, the TDR meter may run the risk of damaging the sampling unit from the sparking caused by its touching of a charged board.
Holder for Package
This is the epoch-making clamp system that allows users to load/unload a variety kinds of packages easily.

A variety kinds of probes can be attached to TDR3030 by simply changing the probe unit or a part of it only.

 Lamination Probe (Kelvin)  TDR Probe  Probe for Pin (Kelvin)
 
Excellent in stability and capable of measuring low resistance of C4 bump.
 
Excellent in frequency characteristic (over 40 GHz).
 
Capable of measuring low resistance of the PGA side of package PCB.

Type TDR3030
Max. Test Area 9.8x5.9" (250x150mm)
Testing Package Size 0.7- 5.5"square (17- 37.5mm square)
Max. No. of Probe ERROR MSG TDR:1, C4 Bump:1, Pin or Pad:2
 Rotate Radius  325o
 Repeatable Accuracy X-Y  ±3 µm
Hotels in Bologna Repeatable Accuracy theta  1o
discount hotels in Knokke-Heist Impedance Accuracy at 28 ohm  28 ±0.4 ohm
 Low Resistance Accuracy  1m ohm ±0.5% Kelvin with Agilent Meter
Weight  2200 lbs.(1000kg)
 Air Requirement: Pressure, Consumption  0.5MPa, 11gal/min.(42l/min.)
Power Supply Single Phase AC100/110/120V 15A 50/60Hz, AC200-240V 8A 50/60Hz
Operating
Conditions
70-75 (21-24 ), 30 - 70%
relative humidity, non-condensing, no dust, no vibration.
System
Requirements

TDR System
1) Control PC & Monitor
2) TDR meter and associated equipment from Tektronix / Agilent Technologies.
[Tektronix]

<TDS8000>x1 Digital sampling Oscilloscope.
<80E04>x1-3 20GHz Dual-Channel Electrical TDR Sampling Module.
<012-1569-00>x1-3 Sampling Module Extender Cable (2 meter).
<015-0560-00>x1-3 SMA Cable
<11801C>x1 Digital sampling Oscilloscope.
<SD24>x1-3 20GHz Dual-Channel Electrical TDR Sampling Module.
<012-1221-00>x1-3 Sampling Module Extender Cable (2 meter).
<015-0560-00>x1-3 SMA Cable
[Agilent Technologies]
<86100A> x1 Digitizing Oscilloscope
<86100A> x1-2 Differential TDR Module
Please confirm the specifications for both 1) & 2) above with our sales.

Low Resistance System
1) Control PC & Monitor
2) Low Resistance meter and associated equipment from Agilent Technologies.
[Agilent Technologies]

<34420A>x1 nanoVolt/micro-Ohm Meter
Please confirm the specifications for both 1) & 2) above with our sales.

Dimension
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |