|  Realizes highly automated TDR measurement of high speed PCB's. Controlled Impedance & Low Resistance Measurements for the high end user of TDR and Resistance measurements. The TDR3030 incorporates a High Accuracy mechanical stage capable of testing pad size to 0.0012" (30µm). With high-speed packaging right around the corner, the TDR3030 is ready for High Accuracy/Resolution type measurements. Measurement item: Controlled Impedance, Low Resistance Testable Terminals: C4 Bump, Pin for PGA, Pad for BGA Interfaces for : Tektronix and Agilent/HP meters Repeatability: ±0.0001"(±3µm)
|
Basic Principle of TDR Measurement | By utilizing Coaxial Probe, high frequency signal that is generated by TDR Generator is loaded on a pattern of PCB. The reflection wave against the signal is measured by the Sampler, and thus the Impedance mismatch is calculated. |
| Ionizer | The Ionizer attached to the arm introduces an air purge prior to the test and neutralizes the static charge of the PCB. Otherwise, the TDR meter may run the risk of damaging the sampling unit from the sparking caused by its touching of a charged board. |
| Holder for Package |  This is the epoch-making clamp system that allows users to load/unload a variety kinds of packages easily. |
| A variety kinds of probes can be attached to TDR3030 by simply changing the probe unit or a part of it only. | Lamination Probe (Kelvin) | TDR Probe | Probe for Pin (Kelvin) |  Excellent in stability and capable of measuring low resistance of C4 bump. |  Excellent in frequency characteristic (over 40 GHz). |  Capable of measuring low resistance of the PGA side of package PCB. | |
| Type | TDR3030 | | Max. Test Area | 9.8x5.9" (250x150mm) | | Testing Package Size | 0.7- 5.5"square (17- 37.5mm square) | | Max. No. of Probe | ERROR MSG TDR:1, C4 Bump:1, Pin or Pad:2 | | Rotate Radius | 325o | | Repeatable Accuracy X-Y | ±3 µm | | Hotels in Bologna Repeatable Accuracy theta | 1o | | discount hotels in Knokke-Heist Impedance Accuracy at 28 ohm | 28 ±0.4 ohm | | Low Resistance Accuracy | 1m ohm ±0.5% Kelvin with Agilent Meter | | Weight | 2200 lbs.(1000kg) | | Air Requirement: Pressure, Consumption | 0.5MPa, 11gal/min.(42l/min.) | | Power Supply | Single Phase AC100/110/120V 15A 50/60Hz, AC200-240V 8A 50/60Hz | Operating Conditions | 70-75 (21-24 ), 30 - 70% relative humidity, non-condensing, no dust, no vibration. | System Requirements | TDR System 1) Control PC & Monitor 2) TDR meter and associated equipment from Tektronix / Agilent Technologies. [Tektronix] <TDS8000>x1 Digital sampling Oscilloscope. <80E04>x1-3 20GHz Dual-Channel Electrical TDR Sampling Module. <012-1569-00>x1-3 Sampling Module Extender Cable (2 meter). <015-0560-00>x1-3 SMA Cable <11801C>x1 Digital sampling Oscilloscope. <SD24>x1-3 20GHz Dual-Channel Electrical TDR Sampling Module. <012-1221-00>x1-3 Sampling Module Extender Cable (2 meter). <015-0560-00>x1-3 SMA Cable [Agilent Technologies] <86100A> x1 Digitizing Oscilloscope <86100A> x1-2 Differential TDR Module Please confirm the specifications for both 1) & 2) above with our sales. Low Resistance System 1) Control PC & Monitor 2) Low Resistance meter and associated equipment from Agilent Technologies. [Agilent Technologies] <34420A>x1 nanoVolt/micro-Ohm Meter Please confirm the specifications for both 1) & 2) above with our sales. | | Dimension |  | |
 |